AC DC Configurable Power Supply Chassis
Mfr Part # | Quantity Available | Price | Series | Package | Product Status | User Configuration | Type | Number of Positions | Voltage - Input | Power (Watts) | Voltage - Isolation | Efficiency | Features | Operating Temperature | Size / Dimension | Height | Approval Agency | Standard Number | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
88 In Stock | 1 : kr.1,757.85000 Box | Box | Active | - | Medical | 4 | 90 ~ 264 VAC, 120 ~ 370 VDC | 650 W | 4 kV | 88.5% | - | -30°C ~ 70°C (With Derating) | 9.84" L x 3.50" W (250.0mm x 89.0mm) | 1.61" (41.0mm) | CB, CE, cURus, EAC, TUV | 60601-1; 62368-1 | |||
90 In Stock | 1 : kr.1,923.13000 Box | Box | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -40°C ~ 70°C (With Derating) | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE | - | |||
1.063 In Stock | 1 : kr.2,006.01000 Box | Box | Active | - | Standard | 4 | 85 ~ 264 VAC | 600 W | - | 89% | - | -20°C ~ 70°C (With Derating) | 5.00" L x 3.00" W (127.0mm x 76.2mm) | 1.61" (41.0mm) | CB, CE, CSA, IEC, UL | 60950-1; 62368-1 | |||
719 In Stock | 1 : kr.2,103.31000 Box | Box | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | - | 86% | - | -20°C ~ 70°C (With Derating) | 5.00" L x 3.00" W (127.0mm x 76.2mm) | 1.61" (41.0mm) | IEC, UL | 60601-1 | |||
99 In Stock | 1 : kr.2,507.46000 Box | Box | Active | - | Standard, Low Noise | 4 | 85 ~ 264 VAC | 600 W | - | 86% | - | -40°C ~ 70°C (With Derating) | 5.00" L x 3.00" W (127.0mm x 76.2mm) | 1.61" (41.0mm) | CB, CE, CSA, IEC, UL | 60950-1; 62368-1 | |||
161 In Stock | 1 : kr.2,629.15000 Box | Box | Active | - | Medical, Low Noise | 4 | 85 ~ 264 VAC | 600 W | - | 86% | - | -40°C ~ 70°C (With Derating) | 5.00" L x 3.00" W (127.0mm x 76.2mm) | 1.61" (41.0mm) | - | 60601-1 | |||
236 In Stock | 1 : kr.2,783.04000 Box | Box | Active | - | Standard | 4 | 85 ~ 264 VAC | 600 W | - | 90% | Remote Sense | -40°C ~ 70°C (With Derating) | 7.00" L x 4.00" W (177.8mm x 101.6mm) | 1.61" (41.0mm) | CB, CE, CSA, IEC, UL | 60601-1 | |||
172 In Stock | 1 : kr.2,929.33000 Box | Box | Active | - | Medical | 6 | 85 ~ 264 VAC | 1200 W | 4 kV | 90% | - | -40°C ~ 70°C (With Derating) | 10.24" L x 5.00" W (260.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | - | |||
105 In Stock | 1 : kr.2,929.40000 Box | Box | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | - | 90% | - | -40°C ~ 70°C (With Derating) | 7.00" L x 4.00" W (177.8mm x 101.6mm) | 1.61" (41.0mm) | CB, CE, CSA, IEC, UL | 60601-1 | |||
29 In Stock | 1 : kr.3,242.10000 Box | Box | Active | - | Medical | 6 | 85 ~ 264 VAC | 1200 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -40°C ~ 70°C (With Derating) | 10.24" L x 5.00" W (260.0mm x 127.0mm) | 1.59" (40.40mm) | CE | - | |||
34 In Stock | 1 : kr.4,522.89000 Box | Box | Active | - | Standard | 6 | 85 ~ 264 VAC | 1340 W | 3 kV | 90% | - | -20°C ~ 70°C | 10.55" L x 5.00" W (268.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | - | |||
69 In Stock | 1 : kr.4,614.77000 Box | Box | Active | - | Standard | 8 | 85 ~ 264 VAC | 1200 W | - | 86% | - | -20°C ~ 70°C (With Derating) | 6.00" L x 6.00" W (152.4mm x 152.4mm) | 1.61" (41.0mm) | CB, CE, CSA, IEC, UL | 60950-1; 62368-1 | |||
44 In Stock | 1 : kr.4,913.55000 Box | Box | Active | - | Medical | 8 | 85 ~ 264 VAC | 1200 W | - | 86% | - | -20°C ~ 70°C (With Derating) | 6.00" L x 6.00" W (152.4mm x 152.4mm) | 1.61" (41.0mm) | CB, CE, CSA, IEC, UL | 60950-1; 62368-1 | |||
45 In Stock | 1 : kr.2,376.98000 Box | Box | Active | - | Standard | 4 | 85 ~ 264 VAC | 750 W | 3 kV | 89% | - | -20°C ~ 70°C | 10.55" L x 3.50" W (268.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | - | |||
28 In Stock | 1 : kr.2,618.68000 Box | Box | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -40°C ~ 70°C (With Derating) | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | - | |||
30 In Stock | 1 : kr.2,063.59000 Box | Box | Active | - | Medical | 6 | 85 ~ 264 VAC | 1200 W | 4 kV | 90% | Conformal Coating | -40°C ~ 70°C (With Derating) | 10.24" L x 5.00" W (260.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | - | |||
34 In Stock | 1 : kr.2,268.93000 Box | Box | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | - | |||
30 In Stock | 1 : kr.2,587.88000 Box | Box | Active | - | Standard, Low Noise | 4 | 85 ~ 264 VAC | 600 W | 3 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | - | |||
53 In Stock | 1 : kr.2,709.57000 Bulk | Bulk | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 94% | - | -40°C ~ 85°C (With Derating) | 8.50" L x 4.50" W (215.9mm x 114.3mm) | 1.50" (38.1mm) | CE | - | |||
43 In Stock | 1 : kr.3,408.92000 Box | Box | Active | - | Medical, Low Noise | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 89% | - | -20°C ~ 70°C | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | - | |||
29 In Stock | 1 : kr.3,622.21000 Box | Box | Active | - | Standard, Low Noise | 6 | 85 ~ 264 VAC | 1200 W | 3 kV | 90% | - | -20°C ~ 70°C | 10.24" L x 5.00" W (260.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | - | |||
35 In Stock | 1 : kr.4,688.87000 Bulk | Bulk | Active | - | Medical | 6 | 85 ~ 264 VAC | 1000 W | 4 kV | 93% | - | -40°C ~ 85°C (With Derating) | 10.00" L x 6.50" W (254.0mm x 165.1mm) | 1.60" (40.6mm) | cCSAus, CE | - | |||
92 In Stock | 1 : kr.5,216.75000 Box | Box | Active | - | Medical | 6 | 85 ~ 264 VAC | 1340 W | 4 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.55" L x 5.00" W (268.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | - | |||
26 In Stock | 1 : kr.1,671.38000 Box | Box | Active | - | Medical | 4 | 85 ~ 264 VAC | 400 W | 4 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.24" L x 3.50" W (260.0mm x 89.0mm) | 1.59" (40.40mm) | CE, cURus | - | |||
29 In Stock | 1 : kr.2,558.29000 Box | Box | Active | - | Medical | 6 | 85 ~ 264 VAC | 1200 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -40°C ~ 70°C (With Derating) | 10.24" L x 5.00" W (260.0mm x 127.0mm) | 1.59" (40.40mm) | CE, cURus | - |